
Why Choose a US Hazmat Storage Explosion-Proof Locker?
Explosion risks arise from improper segregation, poor ventilation, incompatible chemical storage, and electrical spark exposure. Our Explosion Proof Locker solutions eliminate these risks using engineered controls, code-compliant construction, and integrated safety systems.
Key Features
- Explosion-proof lighting, switches & electrical systems (Class I, Div 1 & 2 / Class II compliant)
- Mechanical or natural ventilation, engineered to required air changes per hour
- Spill containment engineered for EPA SPCC compliance
- Fire ratings from non-rated to 4-hour fire-rated wall/roof assemblies
- Heavy welded steel construction
- Static grounding lugs & bonding options
- Explosion relief panels (optional, based on chemical class)
- Integrated shelving, drum racks, and chemical-compatible interior finishes
- Climate control options with explosion-proof HVAC systems
- Custom dimensions—built to fit any site condition
Every US Hazmat Storage unit is designed, engineered, fabricated, delivered, and installed by our in-house team.
Engineered Compliance for Explosion-Proof Storage
Explosion-proof storage requires compliance with multiple federal and state regulations. Our lockers are engineered to satisfy the following:
OSHA 29 CFR 1910
- Hazardous materials handling
- Flammable liquids
- Electrical classifications
- Training and labeling
NFPA Codes
- NFPA 30 – Flammable & Combustible Liquids
- NFPA 33 – Spray Application Using Flammables
- NFPA 70 (NEC) – Hazardous Location Electrical Systems
- NFPA 400 – Hazardous Materials Code
EPA Regulations
- SPCC Secondary Containment
- Clean Water Act compliance
- Waste accumulation and hazardous waste storage
FEMA & Local AHJ Requirements
- Construction standards
- Setback and site placement
- Fire marshal approvals
US Hazmat Storage remains involved through permitting, engineering submittals, and site-specific approvals so your locker arrives ready for use and fully compliant.
Modular Explosion-Proof Storage Lockers – Built to Your Application
We tailor every explosion-proof locker to the chemical hazards stored, including:
- Flammable liquids (Class IA, IB, IC)
- Combustible liquids
- Solvents
- Aerosols
- Paints & coatings
- Resins & epoxies
- Fuels & oils
- Hazardous waste accumulation
- Lithium-ion battery storage (with specialized battery-rated assemblies)
- Combustible dust environments
Whether you need small-volume isolated storage or a fully engineered chemical storage building, our modular systems ensure your operation meets the highest safety standards.
Fire-Rated Options Up to 4 Hours
Explosion-proof storage is frequently combined with fire-rated construction to provide both blast-safe and fire-rated protection.
We offer:
Non Fire-Rated (0-Hour)
For remote outdoor placement away from structures.
1-Hour Fire Rating
Meets basic requirements for many flammable storage applications.
2-Hour Fire Rating
Allows placement closer to existing buildings.
4-Hour Fire Rating (Highest Level)
For high-risk environments, occupied facilities, manufacturing operations, or areas requiring maximum separation from personnel and structures.
Our 4-hour fire-rated explosion-proof lockers include:
- High-mass steel and fire-rated insulation systems
- Fire-tested assemblies
- Fire-rated doors
- Industrial fire dampers and closures
- Fire protection layers engineered to UL standards
Outdoor Explosion-Proof Storage Lockers
Outdoor placement is often preferred for hazardous or explosion-risk environments. US Hazmat Storage designs fully weatherproof exterior storage lockers with features including:
- Snow, wind, and seismic ratings for any region
- Industrial-grade coatings
- Climate control packages
- Weather-protected explosion-proof electrical systems
- Integrated ramps, forklift pockets & equipment access
- Corrosion-resistant structural steel
- Roof overhangs or vestibules for protected access
These outdoor lockers are designed to withstand decades of service in harsh industrial environments.
Custom Explosion-Proof Locker Options
Every unit can be configured with:
Electrical & Environmental Systems
- Explosion-proof LED lighting
- Explosion-proof switches & conduit
- Intrinsically safe wiring
- Class I/II HVAC systems
- Temperature-controlled interior
- Humidity control
Safety Systems
- Gas detection
- Emergency shutoff systems
- Fire monitoring
- Sprinkler-ready infrastructure
- Overfill & spill detection
Interior Build Options
- Heavy-duty shelving
- Drum & tote storage racks
- Forklift-friendly floor systems
- Floor drains or sealed containment basins
Exterior Build Options
- Roll-up doors
- Personnel doors
- Custom door swings
- Custom colors
- Platform decks
- Catwalks
- Ramps and transitions
Explosion-Proof Locker Applications
Explosion-proof storage lockers are critical for:
- Paint & coatings facilities
- Chemical manufacturing
- Aerospace & defense operations
- Utilities & energy companies
- Automotive manufacturing
- Universities & research labs
- Pharmaceutical production
- Warehousing and distribution
- Hazardous waste collection sites
- Manufacturing plants
- Construction sites
- Government & military installations
Every industry has its own compliance pathway, and we build precisely to your sector’s standards.

Turnkey Design, Engineering, and Delivery
Our process supports your project from start to finish:
- Hazard Assessment & Consultation
We evaluate chemical classifications, volumes, electrical environments, and workflow needs. - Engineering & Drawings
Fully stamped engineering packages available in all 50 states. - Fabrication
Precision-welded steel construction in our American manufacturing facilities. - Delivery & Placement
Seamless on-site setup with forklift or crane. - Activation & Training
Ensuring your team is ready to operate safely.
US Hazmat Storage is your single-source partner from concept to completion.
Frequently Asked Questions
An explosion-proof locker is a hazardous materials storage building engineered to prevent ignition of flammable vapors, gases, or dusts. It uses explosion-proof electrical components, compliant ventilation, and segregated steel construction to isolate hazards.
Yes. OSHA 1910 and multiple NFPA codes require explosion-proof electrical systems and segregated storage when:
- Storing flammable liquids
- Handling Class I or II materials
- Storing volatile chemicals indoors
- Placing materials in hazardous locations
Our units meet all required code pathways.
Yes. Explosion-proof and fire-rated construction can be combined.
We offer:
- 0-hour
- 1-hour
- 2-hour
- 4-hour fire-rated explosion-proof lockers
This ensures maximum separation from occupied structures.
Yes.
Explosion-proof storage requires:
- Mechanical ventilation
- Explosion-proof fan assemblies
- Minimum air changes per hour
- Explosion-proof intake and exhaust
- Bonding & grounding
All units are built to meet these requirements.
Yes — if allowed by code and fire marshal requirements. Indoor units typically require:
- Fire ratings
- Ventilation ducting
- Explosion-proof electrical
- Clearance and setback considerations
Outdoor placement is usually preferred for explosive hazards.
Every locker is built to order.
Sizes range from:
- 4′ × 6′ small-volume lockers
- Up to 40′ custom buildings
- Multi-room or multi-bay storage structures
Yes.
All units include full stamped engineering for all 50 states.
Yes.
All units include spill containment designed to EPA SPCC requirements and compatible with localized permitting.










