• Chemical Storage & Life Safety Solutions
  • Talk To Expert : 877-959-0747

Fire-Rated Hazmat Locker | 1–4 Drum Fire-Rated Chemical Storage Buildings

Fire-Rated Hazmat Locker | 1–4 Drum Fire-Rated Chemical Storage Buildings

Fire-Rated Hazmat Locker

1–4 Drum Fire-Rated Chemical Storage Buildings — Custom-Engineered for Full Compliance

A Fire-Rated Hazmat Locker from US Hazmat Storage is engineered for compliant, segregated storage of flammable and combustible liquids, hazardous materials, chemicals, paints, solvents, coatings, and industrial substances that require temperature protection and mandatory fire separation from personnel and occupied facilities.

Designed for 1-drum, 2-drum, and 4-drum configurations with optional shelving, pallet platforms, and mixing spaces, our standard fire-rated lockers deliver UL-classified fire resistance, built-in spill containment, mechanical or natural ventilation, and full compliance with EPA, OSHA, NFPA, IFC, and local AHJ requirements.

For organizations with larger storage needs, US Hazmat Storage also engineers fully custom fire-rated buildings for 20, 50, or even 500+ drums, IBC totes, chemical pallets, and bulk containers—complete with climate control, explosion relief, hazardous material segregation bays, mechanical and electrical integration, and turnkey on-site activation.

No matter the size, every unit is designed, fabricated, and finished by our in-house steel manufacturing team with more than 40 years of custom industrial building experience.

FireSAFE 4X Hazmat Storage Locker

Why Choose a Fire-Rated Hazmat Locker?

Fire-rated chemical storage is required when hazardous materials must be stored:

  • Outside or adjacent to occupied buildings
  • Near property lines or public access points
  • Within proximity restrictions set by local fire codes
  • Indoors, where fire separation walls are required
  • In industrial zones where fire exposure risk is elevated
  • In processes involving flammable vapors or heat-sensitive materials

Our fire-rated lockers offer non-combustible construction, UL fire-resistant insulation, and engineered separation barriers that maintain structural integrity during high-temperature exposure. This protects chemicals, personnel, and property—and ensures your facility passes local inspections.

OSHA COMPLIANT
NFPA COMPLIANT
EPA COMPLIANT

Engineered Fire Ratings: 2-Hour to 4-Hour Fire-Rated Construction

US Hazmat Storage offers multiple fire-rated protection levels to satisfy code-driven requirements:

2-Hour Fire-Rated Hazmat Lockers

Ideal for most industrial use cases, these structures provide:

  • 2-hour fire separation from occupied buildings
  • UL-classified, insulated panel assemblies
  • NFPA 30-compliant construction
  • Reinforced steel framing
  • Exterior/interior fire protection between stored materials and the facility

4-Hour Fire-Rated Hazmat Lockers

Required for the strictest compliance zones, including high-risk industrial, manufacturing, aviation, pharmaceutical, government, and defense facilities.

These units include:

  • 4-hour outdoor fire-rated wall and roof assemblies
  • Maximum protection for flammable liquids or reactive materials
  • High-density mineral wool insulated panels
  • Enhanced fire barrier separation
  • Optional redundant ventilation, remote monitoring, and advanced fire suppression integration

Both construction types meet or exceed EPA 40 CFR, OSHA 29 CFR 1910, NFPA 30, NFPA 400, IFC, and local authority requirements.

Chemical Storage Drum on Handtruck

1–4 Drum Fire-Rated Hazmat Lockers

US Hazmat Storage specializes in compact, single-drum and multi-drum fire-rated storage. Perfect for facilities managing small quantities of hazardous materials, these units offer:

1-Drum Fire-Rated Locker

For isolated storage of a single 55-gallon drum containing flammables, corrosives, or regulated chemicals.
Includes built-in spill containment, self-closing doors, natural ventilation, and fire-rated wall assemblies.

2-Drum Fire-Rated Locker

Ideal for small-batch processes, daily use chemicals, and flammable liquids that require immediate but secure access outside of occupied areas.

4-Drum Fire-Rated Locker

Our best-selling configuration, providing compliant storage for a full 4-drum spill pallet.
Add-on options include:

  • Drum racks
  • Shelving for smaller containers
  • Temperature control
  • Explosion-proof electrical
  • Mechanical ventilation
  • Leak detection
  • Fire suppression systems

These units offer maximum compliance in a compact footprint, without the cost of a full-scale building.

Scalable Compliance from 1 to Hundreds of Chemical Storage Drums or Fully Custom Multi-Bay Storage Building

When your facility requires more than 1–4 drums, US Hazmat Storage engineers fully custom fire-rated chemical storage buildings to store:

  • 1-100’s of drums
  • 1-100’s of IBC totes
  • Mixed pallets of chemical storage containers
  • Bulk flammable material storage
  • Temperature-controlled hazardous materials
  • Segregated incompatible materials

We deliver:

  • Multi-bay layouts
  • Internal firewalls
  • 2-hour or 4-hour separation between bays
  • Explosion-proof electrical systems
  • Custom ventilation and HVAC
  • Climate stability for heat-sensitive chemicals
  • Integrated mixing, dispensing, and pumping areas
  • Overhead monorails and drum trolleys
  • Roll-up doors and forklift access

If you can describe the workflow, we can engineer a custom-built hazmat building to streamline it.

nitric acid

Compliant Construction for Every Material Class

US Hazmat Storage designs buildings for safe storage of:

  • Class I flammable liquids
  • Class II and III combustible liquids
  • Corrosives
  • Paints, inks, dyes, and coatings
  • Oxidizers
  • Acids and bases
  • Reactive chemicals
  • Pesticides
  • Industrial solvents
  • Aerosol containers
  • Lithium battery packs (with optional blast relief and detection systems)

Our engineering team will size and configure your building to match the exact requirements of your chemical inventory.

Spill Containment & Environmental Protection

Every fire-rated hazmat locker includes:

  • Integrated, sealed steel spill sump
  • Forklift-accessible base or steel skids
  • Galvanized grating floors
  • Leak-tight secondary containment
  • Industrial epoxy coatings (optional)
  • Double-walled construction available

Containment capacities meet or exceed EPA and SPCC requirements for worst-case spill scenarios.

Spill Containment Shelving
Air Ventilation System

Ventilation, Explosion Protection & Mechanical Systems

Fire-rated lockers can be equipped with:

  • Gravity or mechanical ventilation
  • Explosion-proof C1D1 or C1D2 electrical components
  • Explosion relief panels
  • Temperature control—HVAC or heat only
  • Dehumidification systems
  • Gas detection and alarm systems
  • Integrated fire suppression
  • Sprinkler tie-in systems

All systems are designed to satisfy local fire marshals, insurance carriers, and AHJ requirements.

Built for Long-Term, Code-Compliant Storage

US Hazmat Storage construction includes:

  • Heavy steel welded base frame
  • Insulated, fire-rated panel assemblies
  • Reinforced roof structures
  • Corrosion-resistant steel finish
  • Climate control options
  • Tamper-resistant, high-security locking hardware
  • Forklift pockets or overhead lifting lugs
  • Exterior powder-coat or epoxy finishes

These buildings perform for decades in industrial and harsh outdoor environments.

Roof Assembly Construction
Offloading hazmat storage locker onto concrete pad via crane

Turnkey Delivery & Setup

US Hazmat Storage provides:

  • Engineering
  • Fabrication
  • Factory testing
  • Delivery
  • Forklift or crane placement guidance
  • On-site commissioning
  • AHJ code compliance support
  • Optional training and operation documentation

Buildings arrive pre-fabricated, pre-wired, and ready to use.

Common Applications

Fire-rated hazmat lockers are used in:

  • Manufacturing plants
  • Chemical facilities
  • Paint, coatings & resin manufacturers
  • Industrial maintenance operations
  • Warehouses & distribution centers
  • Government & military installations
  • Utilities & power generation plants
  • Aviation, marine, and transportation hubs
  • Construction sites
  • Universities & research labs
  • Pharmaceutical manufacturing
  • Municipal public works

FAQ — Fire-Rated Hazmat Locker Compliance

A fire-rated locker is built using UL-classified fire-resistant assemblies that maintain structural integrity during a fire for a defined period (2 or 4 hours).

Yes, when storing flammables outside or within proximity limits of occupied buildings, fire marshals typically require 2-hour or 4-hour fire separation.

  • OSHA (29 CFR 1910)
  • EPA (40 CFR and SPCC)
  • NFPA 30 / NFPA 400
  • IFC
  • Local Authorities Having Jurisdiction

Yes. Certified spill containment is included in all units.

Absolutely. We offer heating, cooling, and humidity control.

Yes. US Hazmat Storage specializes in large-scale engineered buildings for 100–500 drums, IBC totes, or entire chemical warehouse annexes.

Start Your Fire-Rated Hazmat Locker Project Today

Whether you require a 1-drum fire-rated locker for daily use chemicals or a multi-bay, climate-controlled chemical storage building that holds hundreds of drums or pallets, US Hazmat Storage provides engineered solutions built to satisfy all compliance regulations.

Speak with our chemical storage specialists for custom design options, pricing, and lead time.

Contact US Hazmat Storage today to begin your fire-rated storage project.